2010年2月27日星期六

Qun Ling Industrial successfully win the bidding of 1000K inverter anti-islanding detection device project

Qun Ling Industrial successfully win the bidding of 1000K inverter anti-islanding detection device project




Warmly congratulated the successful tenderer National Grid Group Ling Industrial Research and Test Center Laboratory for Solar Power sets of anti-islanding detection device project, which includes: 2 sets of 1000K, and anti-islanding detection of grid-connected inverter device, a Taiwan anti-islanding detection device 200K , 1 30K anti-islanding detection device;



Ling from the group's marketing department sales data aware, anti-islanding detection device is also used in: China Product Certification Center (CQC) Laboratory, Chinese Academy of Sciences electrician, EPRI, numerous measures have prompted many colleges and universities Electric Experiment room, total sales in China more than 100 units.



Qun Ling, is the only professional production of anti-island protection experiment detecting device can be customized according to various test standards: 1, IEC62116-2008 standard; 2, Beijing Jianheng CNCA-CTS004: 2009 new standards; 3, the German TUV Certification with the latest standard DIN VDE 0126-1-1; 4, the U.S. regulatory IEEE1547/IEEE1547.1 standards; 5, Australia and regulations AS4777 standards; can be produced according to the above criteria, and grid-connected inverter island test for detection devices, for the user traffic tailor-made to meet the different needs of field testing.



The following standard products to meet the Beijing Jianheng CGC/GF001-2009 and IEC62116-2008 test for detection requirements:



ACLT-3803M resistive, inductive, capacitive load power are the 33K, to meet the following 30KW islanding detection of grid-connected inverter:



Resistive load :0-32 .97 KW adjustable, step amplitude 0.01KW; current can be separately shown in the control panel;



Inductive load :0-32 .97 KVA continuously adjustable, step amplitude 0.01KVA; current can be separately shown in the control panel;



Capacitive load :0-32 .97 kvar continuously adjustable, step amplitude 0.01kvar; current can be separately shown in the Control Panel.



ACLT-3830M resistive, inductive, capacitive load power are 110K, and below to meet the 100kWp islanding detection of grid-connected inverter:



Resistive load :0-109 .97 KW adjustable, step amplitude 0.01KW; current can be separately shown in the control panel;



Inductive load :0-109 .97 KVA continuously adjustable, step amplitude 0.01KVA; current can be separately shown in the control panel;



Capacitive load :0-109 .97 kvar continuously adjustable, step amplitude 0.01Kvar; current can be separately shown in the Control Panel.



ACLT-3860M resistive, inductive, capacitive load power are 210K, and below to meet the 200kWp islanding detection of grid-connected inverter:



Resistive load :0-209 .97 KW adjustable, step amplitude 0.01KW; current can be separately shown in the control panel;



Inductive load :0-209 .97 KVA continuously adjustable, step amplitude 0.01KVA; current can be separately shown in the control panel;



Capacitive load :0-209 .97 kvar continuously adjustable, step amplitude 0.01Kvar; current can be separately shown in the Control Panel.



ACLT-38160M resistive, inductive, capacitive load power, respectively 529K, satisfy the following 500KW grid-connected inverter islanding detection:



Resistive load :0-529 .7 KW adjustable, step amplitude 0.1KW; current can be separately shown in the control panel;



Inductive load :0-529 .7 KVA continuously adjustable, step amplitude 0.1KVA; current can be separately shown in the control panel;



Capacitive load :0-529 .7 kvar continuously adjustable, step amplitude 0.1Kvar; current can be separately shown in the Control Panel.



ACLT-38300M resistive, inductive, capacitive load power are 1080K, and the following to meet the 1000kWp islanding detection of grid-connected inverter:



Resistive load :0-1079 .7 KW adjustable, step amplitude 0.1KW; three-phase resistive current can be separately shown in the control panel;



Inductive load :0-1079 .7 KVA continuously adjustable, step amplitude 0.1KVA; three-phase inductive current can be separately shown in the control panel;



Capacitive load :0-1079 .7 kvar continuously adjustable, step amplitude 0.1kvar; three-phase capacitive current can be separately shown in the Control Panel.



To learn more about power inverter, please visite http://www.szpowerinverter.com/ and http://www.bestekltd.com/, or mail to sale38@0102.cn.

没有评论: